Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the exhaust gas recirculation (EGR) valve electrical connector.
- Remove the bolts and the EGR valve.
Installation Procedure
- Clean the cylinder head mating surface.
- Install a new EGR valve gasket.
Caution: Refer to Fastener Caution in the Preface section.
- Install the EGR valve with the retaining bolts.
Tighten
Tighten the EGR valve retaining bolts to 30 N·m (22 lb ft).
- Connect the EGR valve electrical connector.
- Connect the negative battery cable.