Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the electrical exhaust gas recirculation (EGR) valve electrical connector.
- Remove the EGR valve retaining bolts.
- Remove the EGR valve.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the EGR valve with the bolts.
Tighten
Tighten the electrical EGR valve retaining bolts to 30 N·m (22 lb ft).
- Connect the EGR valve electrical connector.
- Connect the negative battery cable.