This diagnostic procedure supports the following DTC:
DTC P0713 Transmission Fluid Temperature (TFT) Sensor Circuit High Voltage
| • | The transmission control module (TCM) detects that the analog-to-digital (A/D) value of transmission fluid temperature (TFT) sensor signal is less than 15 and the minimum A/D value is more than 943, when it is past 15 minutes after ignition ON -- A/D value 943:4.7 volts. |
| • | After one occurrence of above detection |
| • | Gear selector position is except park and neutral |
| • | Engine revolution is 400 RPM or greater |
| • | The TCM will request the illumination of the hold lamp and store the DTC when the TCM detects a failure on the first ignition cycle. |
| • | The TCM judges the temperature of the transmission fluid is 200°C (392°F). |
| • | No lockup control |
| • | No 4th gear |
| • | No self-learning control |
| • | No timing solenoid control N-D |
| • | The TCM turns OFF the hold lamp when no further failures are detected on the next ignition cycle. |
| • | The scan tool can clear the DTC from the TCM history. |
| • | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. |
| • | The TCM detects the temperature of the transmission fluid is between 0-150°C for 10 seconds continuously. |
| • | The wiring harness or connector between the TFT sensor and the TCM |
| • | The TFT sensor |
| • | The TCM |
Step | Action | Values | Yes | No |
|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Automatic Transmission? | -- | Go to Step 2 | |
2 |
Is the hold lamp ON? | -- | Go to Step 3 | Go to Step 5 |
3 |
Is DTC P0713 displayed? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the measurement within the specified values? | 10°C (50°F) 5.80-7.09 KΩ 110°C (230°F) 0.231-0.263 KΩ | Go to Step 6 | Go to Step 7 |
5 | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair? | -- | System OK | -- |
6 |
Is the connection condition OK? | -- | Go to Step 8 | Go to Step 5 |
7 |
Is the measurement within the specified values? | 10°C (50°F) 5.80-7.09 KΩ 110°C (230°F) 0.231-0.263 KΩ | Go to Step 9 | Go to Step 10 |
8 |
Is DTC displayed? | -- | Go to Step 2 | System OK |
9 |
Is the condition OK? | -- | System OK | Go to Step 5 |
10 |
Is the condition found? | -- | Go to Step 12 | Go to Step 11 |
11 |
Is the condition OK? | -- | System OK | Go to Step 5 |
12 | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Inspection . Did you complete the repair? | -- | System OK | -- |
This diagnostic procedure supports the following DTC:
DTC P0713 Transmission Fluid Temperature (TFT) Sensor Circuit High Voltage
| • | The transmission control module (TCM) detects that the analog-to-digital (A/D) value of the transmission fluid temperature (TFT) sensor signal is less than 15 and the minimum A/D value is more than 943, when it is past 15 minutes after ignition ON--A/D value 943:4.7 volts. |
| • | After one occurrence of above detection |
| • | Gear selector position is except park and neutral |
| • | Engine revolution is 400 RPM or greater |
| • | The TCM will request the illumination of the malfunction indicator lamp (MIL) and store the DTC when the TCM detects a failure on the first ignition cycle. |
| • | The TCM judges the temperature of the transmission fluid is 200°C (392°F). |
| • | No lockup control |
| • | No 4th gear |
| • | No self-learning control |
| • | No timing solenoid control N-D |
| • | The TCM turns OFF the MIL when no further failures are detected on the next ignition cycle. |
| • | The scan tool can clear the DTC from the TCM history. |
| • | The TCM clears the DTC from the TCM history memory after 40 consecutive ignition cycles without fault. |
| • | The TCM detects the temperature of the transmission fluid is between 0-150°C for 10 seconds continuously. |
| • | The wiring harness or connector between the TFT sensor and the TCM |
| • | The TFT sensor |
| • | The TCM |
Step | Action | Values | Yes | No |
|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Automatic Transmission? | -- | Go to Step 2 | |
2 |
Is the malfunction indicator lamp (MIL) ON? | -- | Go to Step 3 | Go to Step 5 |
3 |
Is DTC P0713 displayed? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the measurement within the specified values? | 10°C (50°F) 5.80-7.09 KΩ 110°C (230°F) 0.231-0.263 KΩ | Go to Step 6 | Go to Step 7 |
5 | Repair the temporary connection failure of the connector. Refer to Wiring Harness and Connector Inspection Diagnosis . Did you complete the repair? | -- | System OK | -- |
6 |
Is the connection condition OK? | -- | Go to Step 8 | Go to Step 5 |
7 |
Is the measurement within the specified values? | 10°C (50°F) 5.80-7.09 KΩ 110°C (230°F) 0.231-0.263 KΩ | Go to Step 9 | Go to Step 10 |
8 |
Is DTC displayed? | -- | Go to Step 2 | System OK |
9 |
Is the condition OK? | -- | System OK | Go to Step 5 |
10 |
Is the condition found? | -- | Go to Step 12 | Go to Step 11 |
11 |
Is the condition OK? | -- | System OK | Go to Step 5 |
12 | Replace the TFT sensor. Refer to Transmission Fluid Temperature Sensor Inspection . Did you complete the repair? | -- | System OK | -- |