| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
RCT Sensor Signal | P00B3 | P00B4 | P00B4* | P00B6 |
Low Reference | -- | P00B4 | P00B4* | P00B6 |
* Internal ECM or sensor damage may occur if the circuit is shorted to B+. | ||||
Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
Operating Conditions: Engine operating in Closed Loop Parameter Normal Range: Varies with ambient temperature | |||
RCT Sensor Signal | 150°C (302°F) | -40°C (-40°F) | -40°C (-40°F)* |
Low Reference | -- | -40°C (-40°F) | -40°C (-40°F)* |
* Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||
The radiator coolant temperature (RCT) sensor, or engine coolant temperature (ECT) sensor 2, is a variable resistor that measures the temperature of the engine coolant in the radiator. The engine control module (ECM) supplies 5 volts to the RCT signal circuit and supplies a ground to the low reference circuit.
The following table illustrates the difference between temperature, resistance, and voltage:
RCT | RCT Resistance | RCT Signal Voltage |
|---|---|---|
Cold | High | High |
Warm | Low | Low |
| • | DTCs P0112 or P0113 are not set. |
| • | The engine run time is greater than 10 seconds. |
| • | The intake air temperature (IAT) is less than 70°C (158°F). |
| • | The DTC runs continuously when either of the above conditions are met. |
| • | DTCs P0112 or P0113 are not set. |
| • | The engine run time is greater than 60 seconds. |
| • | The intake air temperature (IAT) is warmer than -7°C (19°F). |
| • | The DTC runs continuously when either of the above conditions are met. |
The ECM detects that the RCT sensor is greater than 149°C (300°F) for greater than 5 seconds.
Note: The scan tool only displays to -40°C (-40°F).
The ECM detects that the RCT sensor is colder than -60°C (-76°F) for greater than 5 seconds.
| • | DTC P00B3 and P00B4 are Type B DTCs. |
| • | The cooling fans will be commanded ON by the ECM. |
DTC P00B3 and P00B4 are Type B DTCs.
| • | As the thermostat opens, the RCT sensor temperature should rise steadily, then stabilize once the thermostat opens completely. |
| • | Test the RCT sensor at various temperature levels in order to evaluate the possibility of a skewed sensor. |
| • | If the vehicle has sat overnight, the RCT sensor and the ECT sensor values should display within 3°C (5°F). |
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Note: The intake air temperature must be between -7 to +70°C (19-158°F) for the DTCs to set.
| ⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
| ⇒ | If greater than the specified range, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the ECM. |
Note: If the fuse in the jumper wire opens, the signal circuit is shorted to a voltage and the sensor may be damaged.
| ⇒ | If less than the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Note: A thermometer can be used to test the sensor off the vehicle.
| ⇒ | If not within the specified range, replace the RCT sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
| • | Control Module References for ECM replacement, setup, and programming |