Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the power door locks diagnostic system check? | -- | Go to Step 2 | |||||||||
2 |
Are one or more of the above DTCs set as a current code? | -- | Go to Step 3 | |||||||||
3 |
Note: Check connector terminals for looseness or damage. Does the test lamp light? | -- | Go to Step 4 | Go to Step 5 | ||||||||
4 | Connect a fused jumper wire between terminal D CKT 9840 (ORN) and terminal A CKT 195 (LT BLU) of the end/lift gate connector. Do the doors lock? | -- | Go to Step 6 | Go to Step 7 | ||||||||
5 | Repair an open in CKT 840 (ORN). Is the repair complete? | -- | -- | |||||||||
6 | Connect a fused jumper wire between terminal D, CKT 840 (ORN) and terminal B CKT 194 (WHT) of the end/lift gate connector. Do the doors unlock? | -- | Go to Step 8 | Go to Step 9 | ||||||||
7 | Repair the open in CKT 195 (LT BLU). Is the repair complete? | -- | -- | |||||||||
8 | Replace the end/lift gate switch. Is the repair complete? | -- | -- | |||||||||
9 | Repair the open in CKT 194 (WHT). Is the repair complete? | -- | -- |