Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the cigar lighter/auxliary outlets circuit description and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify that the console cigar lighter is inoperative. Does the console cigar lighter operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Connect a test lamp from the Auxiliary Power Outlet, Floor Console harness side connector cavity A to ground. Did the test lamp light? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open or short to ground in CKT 1040 (ORN) between the IP fuse block and the floor console outlet. Refer to Circuit Testing and Wiring Repairs then replace the fuse. Is the repair complete? | -- | Go to Step 8 | -- |
5 | Connect a test lamp from the Auxiliary Power Outlet, Floor Console harness side connector cavity A to cavity B. Did the test lamp light? | -- | Go to Step 6 | Go to Step 7 |
6 | Replace the accessories power receptacle, floor console. Is the repair complete? | -- | Go to Step 8 | -- |
7 | Repair the open or high resistance in CKT 1050 (BLK) between the floor console outlet and G206. Refer to Circuit Testing and Wiring Repairs then check or replace the fuse. Is the repair complete? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |