The number(s) below refer to the step number(s) on the diagnostic table.
This step will test the if the sunroof will slide to the open position. If it opens, then inspect the sunroof limit switch LS2 for a stuck switch causing an intermittent short to ground.
Testing for a short to ground in the sunroof limit switch LS2 circuit or a stuck or closed limit switch.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: Sunroof Schematics DEFINITION: Sunroof only slides between the closed and vent positions, does not open. | ||||
1 | Did you perform A Diagnostic System Check - Power Sunroof? | -- | Go to Step 2 | |
Operate the power sunroof to the open position. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | |
3 |
Does the voltage measure near the specified value? | 4.5-5.5 V | Go to Step 6 | Go to Step 4 |
Did you find and correct the condition? | -- | Go to Step 7 | Go to Step 5 | |
5 | Replace the sunroof opening position switch. Refer to Sunroof Opening Position Switch Replacement . Did you complete the replacement? | -- | Go to Step 7 | -- |
6 | Replace the sunroof module. Refer to Sunroof Control Module Replacement . Did you complete the replacement? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |