The SIR scan tool data definitions contain a brief description of all SIR related
parameters available on the scan tool. The parameters that are available on the scan
tool are listed below in alphabetical order.
8-Digit GM Part Number: The scan tool displays an 8-digit part
number. This number is the GM part number that is stored within the sensing and diagnostic
module (SDM) memory.
ADS A/D: The scan tool displays 0-20 volts. This
is the auxiliary discriminating sensor signal input signal into the SDM.
ADS Monitoring: The scan tool displays whether the ADS Monitoring
is enabled or disabled.
Calibration ID: The scan tool displays a 4-digit number. This
calibration ID is the check sum of the SDM read only memory contents.
Component Serial Number: The scan tool displays the SDM component
serial number.
Driver Side Belt Status: The scan tool displays whether the
driver seat belt is buckled or unbuckled.
Ignition Voltage: The scan tool displays 0-20 volts.
This is the system voltage measured by the SDM between the ignition input and ground.
Julian Date of Build: The scan tool displays a 3-digit number.
An example would be 723. 723 is July 23 which is day 204 based on the
Julian Calendar.
PROM ID: The scan tool displays a 4-digit number. This number
is the programmable read-only memory (PROM) ID.
Year Module Built: The scan tool displays what year the module
was built.