Compressor Control Switches Install HT6/HD6
Tools Required
J 5403 Snap Ring
Pliers
Important: If you reinstall an existing control switch in the compressor, use a
new O-ring and a new retainer ring. An O-ring and a retainer ring is included
in a new switch kit.
- Lubricate the new O-ring using clean refrigerant oil.
- Install the new O-ring into the groove in the switch cavity.
- Lubricate the control switch housing using clean refrigerant oil.
- Install the switch (4) into the switch cavity until the
switch bottoms in the cavity.
- Using the J 5403
,
install the switch retaining ring. Ensure that the high point of the curved
sides is adjacent to the switch housing. Ensure that the retaining ring is
properly seated in the switch cavity retaining groove.
- Leak test according to bench test procedure.