Removal Procedure
- Push up on the J-spring in order to release
the storage compartment door.
- Firmly pull rearward to release the recirculation actuator (2)
locking tab.
Important: The air inlet door is behind the air distribution duct.
- Remove the actuator rod from the recirculation door (1) by pushing the
actuator up and to the left.
- Disconnect the vacuum connector from the recirculation actuator (2).
- Remove the recirculation actuator (2).
Installation Procedure
- Install the recirculation actuator (2).
- Connect the vacuum connector to the recirculation actuator (2).
- Install the actuator rod to the recirculation door (1)
by placing the hole in the actuator rod over the hook on the recirculation door lever.
- Align the recirculation actuator with the recirculation door assembly
and firmly push forward to engage the recirculation actuator locking tab.
- Push up on the J-spring in order to return
the storage compartment door to the normal position.