Air Conditioning (A/C) High Pressure Switch Replacement for Chevrolet Blazer - 4WD - RHD 2002
Tools Required
J 39400-A Halogen
Leak Detector
Removal Procedure
- Recover the refrigerant
from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Resonator Replacement
in Engine Controls -
4.3L.
- Disconnect the A/C high pressure switch electrical connector (2).
- Remove the A/C high pressure switch connector retaining ring.
- Remove the A/C high pressure switch from the A/C Compressor.
Installation Procedure
- Install the A/C high pressure
switch to the A/C Compressor.
- Install the A/C high pressure switch connector retaining ring.
- Connect the A/C high pressure switch electrical connector (2).
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Resonator Replacement
in Engine Controls -
4.3L.
- Evacuate and recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fitting(s) of the repaired or reinstalled components
using the J 39400-A
.