Tools Required
• | J 26549-E Orifice
Tube Remover or Equivalent |
Removal Procedure
- Recover the refrigerant from the system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the evaporator tube from the evaporator (1). Refer
to
Evaporator Tube Replacement
.
- Remove the O-ring seal and discard.
- Use the J 26549-E
in order to remove the expansion (orifice)
tube (2).
- If you have difficulty removing a restricted or plugged expansion
(orifice) tube, use the following procedure:
5.1. | Remove as much of any impacted residue as possible. |
| Notice: If the system has a pressure switch near the expansion
(orifice) tube location, it should be removed prior to heating the pipe to
avoid damage to switch.
|
5.2. | Carefully apply heat with a heat gun (hair dryer, epoxy
dryer, or equivalent) approximately 7 mm (0.25 in) from the
dimples on the inlet pipe. DO NOT overheat the pipe. |
5.3. | While applying heat, use the J 26549-E
or equivalent in order to grip the expansion (orifice) tube. |
5.4. | Use a turning motion along with a push-pull motion in order to
loosen the impacted expansion (orifice) tube. |
Remove the expansion
(orifice) tube.
Installation Procedure
Important: Install the shorter screen end of the expansion (orifice) tube into
the evaporator first.
- Use the J 26549-E
in order to install the expansion (orifice) tube (2).
- Coat the new O-ring seal with 525 viscosity refrigerant
oil.
- Install the new O-ring seal.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the evaporator tube to the evaporator (1).
Tighten
Tighten the evaporator tube to 28 N·m (21 lb ft).
- Evacuate and recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fitting(s) of the repaired or reinstalled components
using the J 39400-A
.