Removal Procedure
- Remove the instrument
panel accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument Panel, Gages and Console.
- Remove the control assembly retaining screws.
- Depress the control assembly retaining tabs and remove the control
assembly from the instrument panel.
- Disconnect the electrical connectors from the control assembly.
Installation Procedure
- Connect the electrical
connectors to the control assembly.
- Install the control assembly into the instrument panel, ensuring
that the control assembly retaining tabs lock into place.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the control
assembly retaining screws.
Tighten
Tighten the control assembly retaining screws to 1.9 N·m
(17 lb in).
- Install the instrument panel accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument
Panel, Gages and Console.