The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Door Lock/Indicator Schematics DEFINITION: This diagnostic should be used to diagnose a complete failure of the power door lock system (lock and unlock). This diagnostic assumes that all the system fuses have been checked for an open and that any shorts to ground in the battery positive voltage circuits have been repaired. If the power door lock system is still inoperative after the battery positive voltage circuits have been repaired and the fuses replaced, continue with the diagnosis. | |||
1 | Did you perform the Power Door System Diagnostic System Check? | Go to Step 2 | |
2 | Actuate all door lock switches to both the lock and unlock positions. Did all the doors lock and unlock? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Did any of the doors lock and unlock from any of the switches? | Go to Step 4 | |
4 |
Did the doors lock and unlock? | Go to Step 12 | Go to Step 5 |
5 |
Did the test lamp illuminate? | Go to Step 6 | Go to Step 13 |
6 | With a test lamp connected to B+, test the ground circuits for the door lock relay at the body relay block. Did the test lamp illuminate? | Go to Step 7 | Go to Step 14 |
7 | Connect a test lamp between the door lock actuator lock circuit at the fuse block and a good ground. Did the test lamp illuminate? | Go to Step 8 | Go to Step 9 |
8 |
Did the test lamp illuminate? | Go to Step 11 | Go to Step 16 |
9 |
Did the test lamp illuminate? | Go to Step 15 | Go to Step 10 |
10 |
Did the test lamp illuminate? | Go to Step 16 | Go to Step 17 |
11 | Test for a short to ground in the door unlock relay control circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 18 |
Repair the open or short to ground in the battery positive voltage circuit between the MIR/LOCK fuse and the door lock switch. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- | |
13 | Repair the open or short to ground in the battery positive voltage supply circuit between the DR LOCK fuse and the door lock and unlock relays. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
14 | Repair the open in the ground circuit for the door lock and unlock relays. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
15 | Replace the door lock relay. Did you complete the repair? | Go to Step 19 | -- |
16 | Replace the door unlock relay. Did you complete the repair? | Go to Step 19 | -- |
17 | Repair the open in the door lock actuator lock and/or unlock circuits. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
18 | Replace the BCM. Refer to Body Control Module Replacement in Body Control System. Did you complete the repair? | Go to Step 19 | -- |
19 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 4 |