The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Defogger Schematics Connector End View Reference: Stationary Windows Connector End Views | |||
1 | Did you perform the Defogger Diagnostic System Check? | Go to Step 2 | |
2 |
Does the rear window defogger indicator illuminate? | Go to Step 3 | Go to Step 10 |
3 | Connect a test lamp between the rear window defogger grid and a good ground. Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 | Connect a test lamp between the left side of the rear window defogger grid and the right side of the rear window defogger grid. Does the test lamp illuminate? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 13 |
Do you hear a click when you command the RR DEFOG relay ON and OFF? | Go to Step 8 | Go to Step 6 | |
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 14 |
7 |
Does the test lamp illuminate? | Go to Step 12 | Go to Step 10 |
8 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 15 |
9 |
Does the test lamp illuminate? | Go to Step 12 | Go to Step 16 |
10 | Test the control circuit of the RR DEFOG relay for an open or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 11 |
11 | Inspect for poor connections at the harness connector of the HVAC Control Module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 17 |
12 | Inspect for poor connections at the RR DEFOG relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 18 |
13 | Repair an open or high resistance in the ground circuit of the rear window defogger. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
14 | Repair an open or high resistance in the ignition voltage circuit of the RR DEFOG relay coil. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
15 | Repair an open or high resistance in the battery positive voltage circuit of the RR DEFOG relay switched input. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
16 | Repair an open or a short to ground in the supply voltage circuit of the rear window defogger. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
17 | Replace the HVAC Control Module. Refer to HVAC Control Module Replacement in HVAC Systems - Automatic. Did you complete the replacement? | Go to Step 19 | -- |
18 | Replace the RR DEFOG relay. Did you complete the replacement? | Go to Step 19 | -- |
19 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |