Tighten
Tighten the catalytic converter bolts to 25 N·m (18 lb ft).
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nuts to 35 N·m (26 lb ft).
Tighten
Tighten the heated oxygen sensor to 42 N·m (31 lb ft).
Tighten
Tighten the bolts to 41 N·m (30 lb ft).
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the crossover pipe nuts to 35 N·m (26 lb ft).
Tighten
Tighten the clamp bolt to 68 N·m (50 lb ft).
Tighten
Tighten the converter bolts to 25 N·m (18 lb ft).
Tighten
Tighten the heated oxygen sensor to 42 N·m (31 lb ft).