Testing Procedure
Tools Required
Important:
• | Both the coolant testers automatically compensate
for temperature. |
• | Make sure the eyepiece of the coolant tester is totally free of
solution before looking through it. |
• | Before each use, swing back the plastic cover at the slanted end
of the coolant tester, exposing the measuring window and the bottom of the
plastic cover. |
• | Wipe the measuring window dry with a tissue or a clean, soft cloth. |
• | Close the plastic cover. |
- Release the tip of the pump from the housing of the J 23688
or the J 26568
.
- Do not remove the clear plastic pump from the J 23688
or the J 26568
.
- Remove the coolant recovery reservoir cap.
- Insert the tube into the coolant recovery reservoir. The tip of
the pump must be below the level of the coolant.
- Press the bulb. Release the pump bulb in order to obtain a sample
of the coolant.
- Bend the tube around the J 23688
or the J 26568
.
Insert the tip of the pump into the cover plate opening.
- Press the pump bulb. Allow a few drops to fall onto the measuring
surface. Do not open the plastic cover when taking readings because any water
evaporation will change the reading.
- Point the coolant concentration tester toward any light source.
Look into the eyepiece.
• | The coolant protection reading is at the point where the dividing
line between light and dark crosses the scale. |
• | The temperature scale is reversed from a standard thermometer
scale. Below zero readings are on the upper half of the scale. |
- If the readings are not clear, properly clean and dry the measuring
surface. Conduct a new test. Make sure there is enough fluid on the measuring
prism.
Calibrating Testers
The J 23688
and the J 26568
are factory calibrated
and sealed. The testers should not require adjustment. If adjustment is required,
do the following adjust procedure:
- Make sure the J 23688
and the J 26568
is between 21-29°C (70-85°F).
- Using distilled water, take a reading. If the reading departs
from a 0°C (32°F) reading on the scale, make a correction by adjusting
the screw on the bottom of the J 23688
and the J 26568
.
Important: Do not remove the screw from the J 23688
and the J 26568
.
- Remove the sealant covering the screw.
- Turn the screw in the direction necessary to adjust the reading
to the 0°C (32°F) line.
- Reseal the screw using a silicone sealant.