The PCM monitors the performance of the EVAP system by applying a predetermined level of vacuum to the EVAP system then monitors the vacuum decay rate. The PCM sets this DTC if the vacuum decay rate is greater than a predetermined value.
• | DTCs P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0420, P0430, P0452, P0453, P0500, P0502, P0503, P1111, P1112, P1114, P1115 or HO2S DTCs are not set. |
• | The ignition voltage is between 10 and 17 volts. |
• | The barometric pressure is more than 75 kPa. |
• | The fuel level is between 15% and 85% of full capacity. |
• | The engine coolant temperature is between 4°C (39°F) and 30°C (86°F). |
• | The intake air temperature is between 4°C (39°F) and 30°C (86°F). |
• | The start up engine coolant temperature and the intake air temperature are within 9°C (16°F) of each other. |
• | The EVAP vacuum decay rate is greater than a predetermined value. |
• | The conditions are present for greater than 2 seconds. |
OR
• | The vacuum present in the EVAP system is greater than a predetermined value. |
• | The conditions are present for greater than 4 seconds. |
Important: This DTC does not report a first failed test. A first fail of this DTC will have a scan tool status as Not Run.
• | The PCM will illuminate the Malfunction Indicator Lamp (MIL) after two consecutive drive trips that the diagnostic runs and fails. |
• | The PCM will record operating conditions at the time the DTC sets. This information will be stored in the Freeze Frame and Failure Records. |
• | A first failure of this DTC will NOT store in Last Test Failed or History. |
• | The PCM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A last test failed, or current DTC, clears when the diagnostic runs and does not fail. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Use a scan tool in order to clear the MIL and the DTC. |
Important: An accurate indication of fuel level is required for the PCM to properly Pass or Fail this DTC. Always diagnose the fuel level sensor DTC's before performing this DTC's diagnostic table. Always inspect for fuel level sensor DTC's stored as History.
Important: The Service Bay Test may have to be performed in cold ambient air temperatures when the vehicle is running a winter grade fuel. The scan tool displays a message when the service bay test does not run.
• | The battery voltage is between 10.5 and 17.5 volts. |
• | The fuel level is between 15% and 85% of the full capacity. |
• | The engine temperature is between 3.5°C (38°F) and 35°C (95°F). |
Perform a physical inspection of the EVAP system. Inspect for the following conditions:
• | A loose, missing, defective, or incorrect fuel tank cap |
• | Incorrectly routed or defective EVAP system vacuum and vapor lines |
• | A stuck closed EVAP Vent Valve |
• | A restricted or blocked EVAP system hose |
• | A restricted or stuck closed fuel tank rollover valves |
• | A malfunctioning or damaged vapor canister |
Inspect for charcoal release from the vapor canister. Refer to the Evaporative Emission System Cleaning procedure.
The vacuum and pressure in the EVAP system is measured in inches of water (H2O). Most gauges measure vacuum in inches of mercury (Hg) and pressure in pounds per square inch (psi). The following shows how the values compare:
in H2O | in Hg | psi |
---|---|---|
1in H2O | 0.07 in Hg | 0.0361 psi |
5 in H2O | 0.36 in Hg | 0.180 psi |
10 in H2O | 0.73 in Hg | 0.361 psi |
15 in H2O | 1.10 in Hg | 0.541 psi |
The numbers below refer to the step numbers on the Diagnostic Table.
An intermittent leak or restriction is indicated if the vehicle passes the Service Bay Test. A fuel tank cap that is loose or off causes this DTC to set.
If the Service Bay Test can not be run, proceed to Step 5. If a fault is not currently present the diagnostic table steps will return you to Step 3.
Testing the vapor canister and the EVAP Vent Valve for restriction.
A Fuel Tank Pressure sensor that does not correctly respond to pressure (or vacuum) causes this DTC to set.
An open fuel tank pressure sensor ground circuit causes this DTC to set. If the fuel tank pressure sensor does not respond to pressure (or vacuum), inspect the ground circuit for an open.
The Fuel Tank Pressure sensor monitors a range from 7.5 in. H2O of pressure to -17.5 in. H2O of pressure (vacuum).
In order to test the Fuel Tank Pressure sensor for vacuum response, command the EVAP Purge Solenoid Valve to 100 percent with the engine running and quickly SEAL the system. Leaving the EVAP Purge Solenoid Valve activated for a longer period of time allows a greater level of vacuum to develop.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
2 | Inspect the EVAP system for the following conditions:
Repair the EVAP system as necessary if you find a condition. Did you find and correct the condition? | -- | ||
3 |
Important: Ensure that The Conditions for Running the Service Bay are met before proceeding with this diagnostic. Refer to Diagnostic Aids. Perform the EVAP system Service Bay Test. Does the vehicle pass the Service Bay Test? | -- | Go to Diagnostic Aids | |
4 |
Does the vacuum drop from the specified value when the EVAP Vent Valve is opened? | 5 in. Hg. | ||
5 |
Does the vacuum drop from the specified value when the vent line is unplugged? | 5 in. Hg. | ||
6 |
Did you find and correct the condition? | -- | ||
7 |
Did you find and correct the condition? | -- | ||
8 |
Important: The following steps require the EVAP pressure/purge diagnostic station J 41413 . Always zero the EVAP Pressure and Vacuum (in. H2O) gauges on the EVAP pressure/purge diagnostic station before proceeding with diagnosis.
Does the Fuel Tank Pressure sensor indicate the actual amount of vacuum in the EVAP system? | -- | ||
9 | Replace the EVAP Vent Valve. Refer to Evaporative Emission Vent Valve Replacement . Is the action complete? | -- | -- | |
10 | Replace the EVAP Vapor Canister. Refer to Evaporative Emission Canister Replacement . Is the action complete? | -- | -- | |
11 | Replace the Fuel Tank Pressure sensor. Refer to Fuel Tank Pressure Sensor Replacement . Is the action complete? | -- | -- | |
12 |
Does the scan tool indicate that this test ran and passed? | -- | ||
13 | Select the Capture Info option and the Review Info option using the scan tool. Does the scan tool display any DTCs that you have not diagnosed? | -- | Go to the applicable DTC | System OK |