Removal Procedure
- Lower the window halfway.
- Remove the front side door trim panel. Refer to
Door Trim Panel Replacement
.
- Remove the water deflector. Refer to
Door Water Deflector Replacement
.
- Support the window in
a position needed to access the window rivets by inserting a rubber wedge
door stops (1) at the front and rear of the window between the window and
the door inner panel.
- Drill out the window rivets
(3) with a 1/4 inch drill bit.
- Remove the window (1) by lifting out of the door.
Important: Inspect the window bushings, window bushing retainers, window front
up stop, window stabilizer pins and window wedges on the window for damage.
- Remove the window bushings and window bushing retainers if necessary,
using a flat-bladed tool covered with cloth body tape.
- Remove the window front up-stop screw if necessary.
- Remove the window front up-stop, front up-stop nut and front up-stop
washer if necessary.
- Remove the window stabilizer screws, if necessary.
- Remove the window stabilizer pins, stabilizer pin nuts and window
wedges if necessary.
Installation Procedure
- Install the window stabilizer
pins, stabilizer pin nuts and window wedges if necessary.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install window
stabilizer screws, if necessary.
Tighten
Tighten the window stabilizer screws to 7 N·m (62 lb in).
- Install the window stabilizer pin nuts, if removed.
Tighten
Tighten the window stabilizer pin nuts to 8 N·m (71 lb in).
- Install the window front up-stop washer, if removed.
- Install the window front up-stop screw, if removed.
Tighten
Tighten the window front up-stop screw to 7 N·m (62 lb in).
- Install the window front up-stop nut if removed.
Tighten
Tighten the window front up-stop nut to 8 N·m (71 lb in).
- Install the window bushings and bushing retainers, if removed.
- Install the window (1) into door so that holes in window bushings
line up with holes in channel.
- Install the window rivets (3) in sequence.
- Install the water deflector. Refer to
Door Water Deflector Replacement
.
- Install the front side door trim panel. Refer to
Door Trim Panel Replacement
.
- Raise the window.