Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Fog Lights Schematics | |||
1 | Did you review the Exterior Lighting System Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Do the fog lamps operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Is only one fog lamp inoperative? | Go to Step 8 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 10 |
5 | Probe the headlamp high beam supply circuit of the fog lamp relay with a test lamp that is connected to battery voltage. Does the test lamp illuminate? | Go to Step 6 | Go to Step 17 |
6 | Probe the park lamps supply voltage circuit of the fog lamp relay with a test lamp that is connected to ground. Does the test lamp illuminate? | Go to Step 7 | Go to Step 15 |
7 | Connect a fused jumper between park lamps supply voltage circuit and the fog lamps supply voltage circuit of the fog lamp relay. Do the fog lamps illuminate? | Go to Step 12 | Go to Step 20 |
8 | Probe the supply voltage circuit of the inoperative fog lamp with a test lamp that is connected to ground. Does the test lamp illuminate? | Go to Step 9 | Go to Step 19 |
9 | Probe between the ground circuit and the supply voltage circuit of the inoperative fog lamp with a test lamp. Does the test lamp illuminate? | Go to Step 14 | Go to Step 18 |
10 |
Does the test lamp illuminate? | Go to Step 11 | Go to Step 16 |
11 | Test for a high resistance or an open in the supply voltage circuit of the fog lamp relay coil. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 13 |
12 | Inspect for poor connections at the harness connector of the fog lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 21 |
13 | Inspect for poor connections at the harness connector of the fog lamp switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 22 |
14 | Inspect for poor connections at the harness connector of the inoperative front fog lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 23 |
15 | Repair a high resistance or an open in the park lamps supply voltage circuit of the fog lamp relay . Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
16 | Repair a high resistance or an open in the park lamps supply voltage circuit of the fog lamp switch . Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
17 | Repair a high resistance or an open in the headlamp high beam supply circuit of the fog lamp relay. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
18 | Repair a high resistance or an open in the ground circuit of the inoperative fog lamp. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
19 | Repair a high resistance or an open in the supply voltage circuit of the inoperative fog lamp. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
20 | Repair a high resistance or an open in the supply voltage circuit of the fog lamps. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
21 | Replace the fog lamp relay. Refer to Fog Lamp Relay Replacement . Did you complete the replacement? | Go to Step 24 | -- |
22 | Replace the fog lamp switch. Refer to Fog Lamp Switch Replacement . Did you complete the replacement? | Go to Step 24 | -- |
23 | Replace the inoperative fog lamp. Refer to Front Fog Lamp Bulb Replacement . Did you complete the replacement? | Go to Step 24 | -- |
24 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Fog Lights Schematics | |||
1 | Did you review the Exterior Lighting System Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Do the fog lamps operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Is only one fog lamp inoperative? | Go to Step 8 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 10 |
5 | Probe the ground circuit of the fog lamp relay coil with a test lamp that is connected to battery voltage. Does the test lamp illuminate? | Go to Step 6 | Go to Step 17 |
6 | Probe the park lamps supply voltage circuit of the fog lamp relay with a test lamp that is connected to ground. Does the test lamp illuminate? | Go to Step 7 | Go to Step 15 |
7 | Connect a fused jumper between park lamps supply voltage circuit and the fog lamps supply voltage circuit of the fog lamp relay. Do the fog lamps illuminate? | Go to Step 12 | Go to Step 20 |
8 | Probe the supply voltage circuit of the inoperative fog lamp with a test lamp that is connected to ground. Does the test lamp illuminate? | Go to Step 9 | Go to Step 19 |
9 | Probe between the ground circuit and the supply voltage circuit of the inoperative fog lamp with a test lamp. Does the test lamp illuminate? | Go to Step 14 | Go to Step 18 |
10 |
Does the test lamp illuminate? | Go to Step 11 | Go to Step 16 |
11 | Test for a high resistance or an open in the supply voltage circuit of the fog lamp relay coil. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 13 |
12 | Inspect for poor connections at the harness connector of the fog lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 21 |
13 | Inspect for poor connections at the harness connector of the fog lamp switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 22 |
14 | Inspect for poor connections at the harness connector of the inoperative front fog lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 23 |
15 | Repair a high resistance or an open in the park lamps supply voltage circuit of the fog lamp relay . Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
16 | Repair a high resistance or an open in the park lamps supply voltage circuit of the fog lamp switch . Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
17 | Repair a high resistance or an open in the ground circuit of the fog lamp relay coil. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
18 | Repair a high resistance or an open in the ground circuit of the inoperative fog lamp. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
19 | Repair a high resistance or an open in the supply voltage circuit of the inoperative fog lamp. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
20 | Repair a high resistance or an open in the supply voltage circuit of the fog lamps. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
21 | Replace the fog lamp relay. Refer to Fog Lamp Relay Replacement . Did you complete the replacement? | Go to Step 24 | -- |
22 | Replace the fog lamp switch. Refer to Fog Lamp Switch Replacement . Did you complete the replacement? | Go to Step 24 | -- |
23 | Replace the inoperative fog lamp. Refer to Front Fog Lamp Bulb Replacement . Did you complete the replacement? | Go to Step 24 | -- |
24 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |