Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the exhaust gas recirculation (EGR) valve connector.
- Remove the EGR valve retaining bolts.
- Remove the EGR valve and the gasket from the EGR valve adapter.
Installation Procedure
- Clean the EGR valve adapter mating surface.
- Install a new EGR valve gasket.
Notice: Refer to Fastener Notice in the Preface section.
- Install the EGR valve with the bolts.
Tighten
Tighten the EGR valve retaining bolts to 30 N·m (22 lb ft).
- Connect the EGR valve connector.
- Connect the negative battery cable.