Step | Action | Values | Yes | No |
---|---|---|---|---|
1 |
Does the digit go on and off? | -- | Go to Step 2 | Go to Step 3 |
2 | Run a self-diagnosis circuit check. Does the display indicate a defect code? | -- | Go to the table for the code that flashes. | -- |
3 | Check fuse F18 in the I/P fuse block. Is this fuse in good condition? | -- | Go to Step 5 | Go to Step 4 |
4 | Replace fuse F18. Is the repair complete? | -- | System OK | -- |
5 |
Is the voltage within the specified value? | 11-14 V | Go to Step 15 | Go to Step 8 |
6 | Measure the voltage between ground and terminal 30 (BN/WH) at the blower relay. Is the voltage within the specified value? | 11-14 V | Go to Step 8 | Go to Step 7 |
7 | Repair any problem found in terminal 85 at the relay connector, or ground G203. Is the repair complete? | -- | System OK | -- |
8 | Replace the blower relay. Is the repair complete? | -- | System OK | -- |
9 |
Is the voltage within the specified value? | 11-14 V | Go to Step 11 | Go to Step 10 |
10 |
Is the repair complete? | -- | System OK | -- |
11 | Measure the resistance between the connector terminals on the blower motor. Does the resistance match the specified value? | 5 ohms | Go to Step 13 | Go to Step 12 |
12 | Replace the blower motor. Is the repair complete? | -- | System OK | -- |
13 | Measure the resistance of circuit between terminal 1 of the blower connector and terminal 30 of the Max HI relay and terminal 2 of the power module. Does the resistance match the specified value? | 0 ohms | Go to Step 15 | Go to Step 14 |
14 | Repair the problem in circuit. Is the repair complete? | -- | System OK | -- |
15 | Measure the resistance of circuit from terminal 4 of the power module connector to ground. Does the resistance match the specified value? | 0 ohms | Go to Step 17 | Go to Step 16 |
16 |
Is the repair complete? | -- | System OK | -- |
17 | Replace the ATC controller. Is the repair complete? | -- | System OK | -- |