• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Coil Ignition Voltage | P0480, P0481, P0691, P0693 | P0480, P0481, P0691, P0693 | -- | -- |
Relay Switch B+ | * | * | -- | -- |
Auxiliary Fan Relay Coil Control | P0481, P0691 | P0481, P0691 | P0481, P0692 | -- |
Main Fan Relay and Fan Control Relay Coil Control | P0480, P0693 | P0480, P0693 | P0480, P0694 | -- |
Relay Switch Controlled Output | * | * | ** | -- |
* Fans inoperative without a DTC. ** Fans always ON without a DTC. |
The engine control module (ECM) commands the fans ON in either high speed or low speed, depending on cooling requirements. In low speed, both fans are turned ON at a reduced speed. High speed has both fans turned ON at full speed.
In low speed operation, the ECM applies ground to the coil side of the auxiliary fan relay. This energizes the coil and applies voltage directly to the auxiliary cooling fan through the switch side of the relay. The auxiliary fan is connected in series to the main cooling fan through the de-energized series/parallel control fan relay. The series circuit operates both fans at low speed.
In high speed operation, the ECM applies a ground to the coil side of the auxiliary fan relay, the control fan relay, and the main fan relay. When energized, the main fan relay applies voltage directly to the main cooling fan through the switch side of the relay. Simultaneously, the auxiliary fan relay and the control fan relay provide ignition voltage and a direct path to ground for the auxiliary cooling fan. With both fans connected in a parallel circuit, each fan receives full voltage and operates at high speed.
• | The ignition voltage is between 8-18 volts. |
• | The engine speed is more than 40 RPM. |
• | The ECM driver transitions from ON to OFF or from OFF to ON. |
The ECM detects an open on the main cooling fan relay control circuit for more than 1 second.
The ECM detects an open circuit on the auxiliary cooling fan relay control circuit for more than 1 second.
The ECM detects a short to ground on the main cooling fan relay control circuit for more than 1 second.
The ECM detects a short to voltage on the main cooling fan relay control circuit for more than 1 second.
The ECM detects a short to ground on the auxiliary cooling fan relay control circuit for more than 1 second.
The ECM detects a short to voltage on the auxiliary cooling fan relay control circuit for more than 1 second.
DTCs P0480, P0481, P0691, P0692, P0693, and P0694 are Type B or Type C DTCs.
DTCs P0480, P0481, P0691, P0692, P0693, and P0694 are Type B or Type C DTCs.
Cooling Fan Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Important: The following tests must be performed on each cooling fan relay.
⇒ | If the test lamp does not illuminate, test the relay coil ignition voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the relay coil ignition voltage circuit fuse is open, test all components connected to the ignition voltage circuit and replace as necessary. |
⇒ | If less than the specified range, test the relay coil control circuit for an open/high resistance or for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the relay coil control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified range, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |