KM-470-B Angular Torque Gage
Note: Before installing the crankshaft balancer unit assembly, perform the crankshaft balancer unit adjustment for the proper operation.
Caution: Refer to Fastener Caution in the Preface section.
• | Tighten bolts to 20 N·m (15 lb ft). |
• | Turn the bolts another 45 degrees using KM-470-B gage . |
• | Install the oil pan scraper and tighten bolts to 8 N·m (71 lb in). |
• | Install the oil suction pipe with the new O-ring and tighten bolts to 8 N·m (71 lb in). |
• | Install the oil pan. Refer to Oil Pan Replacement. |