Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
Caution: Gasoline or gasoline vapors are highly flammable. A fire could occur
if an ignition source is present. Never drain or store gasoline or diesel
fuel in an open container, due to the possibility of fire or explosion. Have
a dry chemical (Class B) fire extinguisher nearby.
- Disconnect the evaporative emission (EVAP) canister purge solenoid valve connector.
- Disconnect the vacuum hoses from the EVAP canister purge solenoid.
- Remove the EVAP canister purge solenoid valve bracket bolt from the intake manifold.
- Unclip the EVAP canister purge solenoid valve from the mounting bracket.
Installation Procedure
- Attach the EVAP canister purge solenoid valve to the mounting bracket.
Caution: Refer to Fastener Caution in the Preface section.
- Install the EVAP canister purge solenoid valve and the mounting bracket to the intake manifold with the bracket bolt.
Tighten
Tighten the EVAP canister purge solenoid valve bracket bolt to 5 N·m (44 lb in).
- Connect the vacuum hoses to the EVAP canister purge solenoid valve.
- Connect the EVAP canister purge solenoid valve connector.
- Connect the negative battery cable.