J 37088-A Fuel Line Disconnect Tool Set
Removal Procedure
- Relieve the fuel system pressure before servicing
any fuel system connection. Refer to the
Metal Collar Quick Connect Fitting Service.
- Remove the retainer from the quick-connect fitting.
Caution: Wear safety glasses when using compressed air, as flying dirt particles
may cause eye injury.
- Blow dirt out of the
fitting using compressed air.
- Choose the correct tool from the
J 37088-A for the size of the fitting. Insert the tool into the female
connector, then push inward in order to release the locking tabs.
- Pull the connection apart.
Notice: If necessary, remove rust or burrs from the fuel pipes with an emery
cloth. Use a radial motion with the fuel pipe end in order to prevent damage
to the O-ring sealing surface. Use a clean shop towel in order to wipe off
the male tube ends. Inspect all the connections for dirt and burrs. Clean
or replace the components and assemblies as required.
- Use a clean shop towel in order to wipe off
the male pipe end.
- Inspect both ends of the fitting for dirt and burrs. Clean or replace
the components as required.
Installation Procedure
Caution: In order to reduce the risk of fire and personal injury, before connecting
fuel pipe fittings, always apply a few drops of clean engine oil to the male
pipe ends.
This will ensure proper reconnection and prevent a possible fuel leak.
During normal operation, the O-rings located in the female connector
will swell and may prevent proper reconnection if not lubricated.
- Apply a few drops
of clean engine oil to the male pipe end.
- Push both sides of the fitting together in order
to snap the retaining tabs into place.
- Once installed, pull on both sides of the fitting
in order to make sure the connection is secure.
- Install the retainer to the quick-connect fitting.
Special Tool
J 37088-A Fuel Line Disconnect Tool Set
Removal Procedure
- Relieve the fuel system pressure before servicing any fuel system connection. Refer to the
Metal Collar Quick Connect Fitting Service.
- Remove the retainer from the quick-connect fitting.
Warning: Wear safety glasses when using compressed air, as flying dirt particles may cause eye injury.
- Blow dirt out of the fitting using compressed air.
- Choose the correct tool from the
J 37088-A for the size of the fitting. Insert the tool into the female connector, then push inward in order to release the locking tabs.
- Pull the connection apart.
Caution: If necessary, remove rust or burrs from the fuel pipes with an emery cloth. Use a radial motion with the fuel pipe end in order to prevent damage to the O-ring sealing surface. Use a clean shop
towel in order to wipe off the male tube ends. Inspect all the connections for dirt and burrs. Clean or replace the components and assemblies as required.
- Use a clean shop towel in order to wipe off the male pipe end.
- Inspect both ends of the fitting for dirt and burrs. Clean or replace the components as required.
Installation Procedure
Warning: In order to reduce the risk of fire and personal injury, before connecting fuel pipe fittings, always apply a few drops of clean engine oil to the male pipe ends.
This will ensure
proper reconnection and prevent a possible fuel leak.
During normal operation, the O-rings located in the female connector will swell and may prevent proper reconnection if not lubricated.
- Apply a few drops of clean engine oil to the male pipe end.
- Push both sides of the fitting together in order to snap the retaining tabs into place.
- Once installed, pull on both sides of the fitting in order to make sure the connection is secure.
- Install the retainer to the quick-connect fitting.