J 45059 Angle Meter
Important: Do not use any sealing material.
Notice: Refer to Fastener Notice in the Preface section.
Important: Always use new cylinder head bolts.
Tighten
• | Tighten the bolts to 30 N·m (22 lb ft). |
• | Tighten the bolts an additional 155 degrees in sequence. Use the J 45059 . |
Tighten
Tighten the cylinder head bolts to 35 N·m (26 lb ft).
J 45059 Angle Meter
For equivalent regional tools, refer to Special Tools.
Note: Do not use any sealing material.
Caution: Refer to Fastener Caution in the Preface section.
Note: Always use new cylinder head bolts.
• | Tighten the bolts to 30 N·m (22 lb ft). |
• | Using the J 45059 meter , tighten the bolts an additional 155 degrees in sequence. |