• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Driver Door Ajar Signal | B2976 00 | 1 | 1 | -- |
Passenger Door Ajar Signal | B2991 00 | 1 | 1 | -- |
Driver Door Latch Ground | -- | 1 | 1 | -- |
Passenger Door Latch Ground | -- | 1 | 1 | -- |
1. Door Ajar Indicator Inoperative |
The body control module (BCM) receives a discrete input from driver and passenger jamb switches. The BCM then communicates this status to the instrument panel cluster (IPC) via a serial data message. The IPC, upon receipt of this serial data message, will illuminate the ajar indicator and also send a serial data massage to the radio to activate the door ajar audible warming when the transmission is removed from PARK and the vehicle speed is greater than 8 km/h (5 mph).
The door ajar switches supply a ground to the BCM when the door is open. Once the door is closed the door ajar switch opens removing the ground to the BCM. The BCM sends a signal to the IPC to illuminate the door ajar indicator when a door is open.
The system voltage is 9-18 volts.
The BCM detects a short to ground in the driver door ajar circuit for longer than 10 minutes.
The door ajar indicator is on at all times.
• | The DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will become a history DTC. |
• | A history DTC will clear after 50 ignition cycles. |
Door Lock/Indicator Schematics
Door Ajar Indicator Description and Operation
Control Module References for scan tool information
Ignition ON, observe the door ajar indicator on the I/P while opening and closing the driver door. The indicator should turn ON and OFF when opening and closing the driver door.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the indicator is illuminated, test the signal circuit terminal 6 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the indicator is not illuminated, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, replace the driver door latch assembly. |
⇒ | If not the specified value, replace the driver door latch assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |