Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect
control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
- Disconnect the hybrid battery. Refer to
Hybrid Battery Service Disconnect/Connect
.
- Remove the generator battery carrier. Refer to
Generator Battery Carrier Replacement
.
- Remove the 2 generator battery fan bolts (2).
- Remove the 12 generator battery cover bolts (1).
- Remove the generator battery wiring harness from the clip (3) on the generator battery cover.
- Remove the generator battery cover.
Important: Removing the interconnect cables will disable the 36 volts within the generator battery control module.
- Remove the generator battery terminal covers (1).
- Remove the generator battery cable nuts (2).
- Remove the generator battery cable leads (3, 4, 5) from the batteries.
- Remove the 3 small wire terminal leads located under the battery cable leads from the batteries.
- Remove the generator battery control module nut (1), and the battery cable (2) from
the stud.
- Remove the generator battery control module nut (3), and the battery cable (4) from the stud.
- Disconnect the generator battery control module electrical connectors (5, 6).
- Remove the generator battery control module bolts (1).
- Remove the generator battery control module (2).
Installation Procedure
- Install the generator battery control module (2).
Notice: Refer to Fastener Notice in the Preface section.
- Install the generator battery control module bolts (1).
Tighten
Tighten the bolts to 8 N·m (71 lb in).
- Position the generator battery temperature sensor wiring harness and the battery cables to the generator
control module.
- Connect the generator battery temperature sensor wiring harness electrical connectors (5, 6) to the generator control module.
- Install the battery cable (4), and the generator battery control module nut (3) to the stud.
Tighten
Tighten the nut to 8 N·m (71 lb in).
- Install the battery cable (2), and the generator battery control module nut (1) to the stud.
Tighten
Tighten the nut to 8 N·m (71 lb in).
- Install the 3 small wire terminal leads to the batteries.
- Install the generator battery cable leads (3, 4, 5) to the batteries.
- Install the generator battery cable nuts (2).
Tighten
Tighten the nut to 8 N·m (71 lb in).
- Install the generator battery terminal covers (1).
- Install the generator battery cover.
- Install the 12 generator battery cover bolts (1).
Tighten
Tighten the bolts to 8 N·m (71 lb in).
- Install the 2 generator battery fan bolts (2).
Tighten
Tighten the bolts to 8 N·m (71 lb in).
- Install the generator battery wiring harness to the clip (3) on the generator battery cover.
- Install the generator battery carrier. Refer to
Generator Battery Carrier Replacement
.
- Connect the hybrid battery. Refer to
Hybrid Battery Service Disconnect/Connect
.