Alignment Procedure
Notice: The new SIR coil assembly will be centered. Improper alignment of the
SIR coil assembly may damage the unit, causing an inflatable restraint malfunction.
- If available remove the yellow tab (2) and save
for reassembly.
- Gently rotate the coil hub (1) clockwise until a slight tension
is present.
- Count the number of revolutions, while gently rotating the coil hub (1)
counter clockwise until a slight tension is present.
- Gently rotate the coil hub (1) clockwise one half of the previously
counted revolutions.
- Rotate the coil hub as required to align the yellow tab (2).
- Install the yellow tab (2) into the coil hub. Use tape if the tab
is unavailable.
Alignment Procedure
Caution: The new SIR coil assembly will be centered. Improper alignment of the SIR coil assembly may damage the unit, causing an inflatable restraint malfunction.
- If available remove the yellow tab (2) and save for reassembly.
- Gently rotate the coil hub (1) clockwise until a slight tension is present.
- Count the number of revolutions, while gently rotating the coil hub (1) counterclockwise until a slight tension is present.
- Gently rotate the coil hub (1) clockwise one half of the previously counted revolutions.
- Rotate the coil hub as required to align the yellow tab (2).
- Install the yellow tab (2) into the coil hub. Use tape if the tab is unavailable.