Removal Procedure
- Remove the HVAC module. Refer to
HVAC Module Assembly Replacement
.
- Disconnect the electrical connector from the recirculation actuator.
- Remove the recirculation actuator screws.
- Remove the recirculation actuator.
- Remove the air inlet assembly screws.
- Remove the air inlet assembly.
Installation Procedure
- Install the air inlet assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the air inlet assembly screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the recirculation actuator.
- Install the recirculation actuator screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the electrical connector to the recirculation actuator.
- Install the HVAC module. Refer to
HVAC Module Assembly Replacement
.
Removal Procedure
- Remove the HVAC module. Refer to
HVAC Module Assembly Replacement.
- Disconnect the electrical connector from the recirculation actuator.
- Remove the recirculation actuator screws.
- Remove the recirculation actuator.
- Remove the air inlet assembly screws.
- Remove the air inlet assembly.
Installation Procedure
- Install the air inlet assembly.
Caution: Refer to Fastener Caution in the Preface section.
- Install the air inlet assembly screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the recirculation actuator.
- Install the recirculation actuator screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the electrical connector to the recirculation actuator.
- Install the HVAC module. Refer to
HVAC Module Assembly Replacement.