EN-47719 Tensioner Compressor
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the timing chain tensioner bolts to 21 N·m (15 lb ft).
Important: Always install a NEW camshaft position actuator filter - located in pilot nose of camshaft - anytime the camshaft position actuator is removed or installed. Refer to Camshaft and Bearings Cleaning and Inspection for filter changing instructions.
Notice: Use only a Torx Plus® Bit when removing or installing the camshaft position actuator fasteners (1). The Torx Plus® design differs from typical Torx® fastener. Use of a standard Torx® bit on Torx Plus® fasteners may result in a rounded out fastener head or incorrect faster torque.
Important: DO NOT use any type of threadlocking compound on the camshaft position actuator mounting bolts. Usage of a threadlocking compound on the threads could lead to contamination of the camshaft position actuator, possibly resulting in potential damage to the actuator.
Tighten
Tighten the bolts to 16 N·m (12 lb ft).
EN-47719 Tensioner Compressor
For equivalent regional tools, refer to Special Tools.
Caution: Refer to Fastener Caution in the Preface section.
Caution: Use only a Torx Plus® Bit when removing or installing the camshaft position actuator fasteners (1). The Torx Plus® design differs from typical Torx® fastener. Use of a standard Torx® bit on Torx Plus® fasteners may result in a rounded out fastener head or incorrect faster torque.
Note: DO NOT use any type of threadlocking compound on the camshaft position actuator mounting bolts. Usage of a threadlocking compound on the threads could lead to contamination of the camshaft position actuator, possibly resulting in potential damage to the actuator.