Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Disconnect the current sensor harness connector (1) from the sensor (2).
- Remove the positive battery cable fuse fastener (3 and cable (2) from the fuse.
- Remove any tape or retainers from the current sensor and cable. Note the location of the current sensor for assembly.
- Slide the current sensor (1) off the cable (2).
Installation Procedure
- Slide the current sensor (1) into position on the cable (2).
- Install tape or retainers to the current sensor and cable as noted during removal.
- Install the positive battery cable fuse fastener (3) and cable (2) to the fuse and tighten to
5 N·m (45 lb in).
- Connect the current sensor harness connector (1) to the sensor (2).
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.