| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the system voltage sensor to detect for a shorted low or shorted high condition.
| • | The engine is running. |
| • | Hybrid mode is active. |
| • | Sensor output voltage is less than 0.2 volt (30.0 volts). |
| • | The 12-volt power supply - 12-volt output voltage is greater than 5 volts for 0.5 ms. |
| • | Sensor output voltage is greater than 3.84 volt (1.56 volts). |
| • | The 12-volt power supply - 12-volt output voltage is greater than 5 volts for 0.5 ms. |
Hybrid system is disabled.
Wake up signal is ON.
Starter/Generator Description and Operation
Control Module References for scan tool information
| ⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming