• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the hybrid battery system voltage for a low and high condition to detect the failure of the 36-volt output voltage sensor that is below or above a valid range.
The engine is running.
• | Sensor signal is less than 0.2 volt for continuous 20 ms. |
• | Sensor signal is less than 0.2 volt for 20 ms and 36-volt battery voltage is greater than 5 volts for 20 ms. |
Sensor output voltage less than 4 volts and 36-volt battery voltage is greater than 5 volts for 20 ms.
• | Stop PWM (MGU shutdown). |
• | APM PWM off. |
Closes 30 seconds after cycle wake up signal.
Possible internal sensor shorted.
Possible internal sensor open.
Starter/Generator Description and Operation
Control Module References for scan tool information
Warning: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming