Disassembly Procedure
Tools Required
J 22912-01 Split
Plate
Caution: When handling parts that have been preheated for installation purposes,
always wear leather welding gloves with a minimum amount of handling time.
Failure to wear leather gloves may result in severe skin burns or personal
injury.
Important: Heat the input shaft, collar and the stopper plate in an approved preheat
oven to approximately 95°C (200°F) just prior to removal. Do not use
an acetylene torch or other open flame. Always allow the preheated parts to
cool after removal. Do not quench the preheated parts with water. Use compressed
air to help in cooling any preheated parts.
- Remove the collar and the stopper plate. Use a J 22912-01
inverted with a press. Discard the
collar and the stopper plate.
- Pull out the following items as an assembly using the J 22912-01
inverted and a press.
• | The 3rd/4th synchronizer |