Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
1 | Perform the function test. Refer to Function Test . Did you find the air delivery incorrect? | Go to Step 2 | System OK | ||||||
2 | Inspect the affected valve actuator for the following conditions:
Are the installations and connections correct? | Go to Step 4 | Go to Step 3 | ||||||
3 | Reinstall the valve actuator or repair the connections as needed. Refer to Vacuum Hose Harness Replacement . Does the condition persist? | Go to Step 4 | System OK | ||||||
4 |
Is the valve operating properly? | Go to Step 6 | Go to Step 5 | ||||||
5 | Repair the valve as needed. Does the condition persist? | Go to Step 6 | System OK | ||||||
6 |
Is the vacuum present? | Go to Step 7 | Go to Step 8 | ||||||
7 | Test for the following using a hand vacuum pump on each vacuum hose at the control assembly:
Did you find and repair the condition? | System OK | Go to Step 9 | ||||||
8 | Inspect for vacuum source to the vacuum tank. Did you find and repair the condition? | System OK | -- | ||||||
9 | Replace the control assembly. Refer to Control Assembly Replacement . Does the condition persist? | -- | System OK |