The plastic expansion tube, with the mesh screen and orifice
is in the evaporator inlet pipe. The orifice tube provides a restriction to
the high-pressure liquid refrigerant in the liquid line, metering the flow
of refrigerant to the evaporator as a low-pressure liquid. The filter screens
on both the inlet and outlet sides protect the expansion tube and orifice
from contamination. Service the tube only as a replacement assembly.
When the engine is turned OFF, after the air conditioning has been operating,
the refrigerant in the system flows from the high-pressure side of the expansion
tube orifice to the low-pressure side until the pressure equalizes. This
is detectable as a faint hissing sound for 30-60 seconds.
The hissing is normal.
When system diagnostics indicate a restricted expansion tube, replacement
of the restricted expansion tube may not be necessary. Metal chips, flakes,
or slivers found on the screen may be removed with compressed air. Reuse
the expansion tube under the following conditions:
• | The plastic frame is not broken. |
• | The expansion tube is not damaged or plugged. |
• | The screen material is not torn. |
• | The screen is not plugged with fine gritty material. |