- Clean all of the oil pump
parts in solvent.
- Inspect the pump cover housing for the following conditions:
• | Porous or damaged casting |
• | Excessive wear or galling |
- Inspect the pressure relief valve for damage. Replace the valve
if the valve is damaged.
- Inspect the gerotor for the following conditions:
- Measure the following
parts:
• | The gerotor cavity depth |
• | The inner gerotor tip clearance |
• | The outer gerotor diameter clearance |
- Replace the pump as an assembly if the housing or gears are worn
beyond specifications.