Tools Required
J 38185 Hose Clamp Pliers
Removal Procedure
- Drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Use the J 38185
in order to
reposition the surge tank pipe clamp (6) from the surge tank outlet hose (5).
- Remove the surge tank pipe (7) from the surge tank outlet hose (5).
- Use the J 38185
in order
to reposition the surge tank pipe clamp (9) from the surge tank pipe (7).
- Remove the outlet hose (10) from the surge tank pipe (7).
Installation Procedure
- Install the outlet hose (10) to the surge tank pipe (7).
- Use the J 38185
in order
to reposition the surge tank pipe clamp (9) to the surge tank pipe (7).
- Install the surge tank pipe (7) to the surge tank outlet hose (5).
- Use the J 38185
in order
to reposition the surge tank pipe clamp (6).
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.