Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions.
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? | Greater than 16°C (60°F) - 345 kPa (50 psi) Greater than 24°C (75°F) - 483 kPa (70 psi) Greater than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the reset button before using the print functionJ 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet panel temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-50°F) | 0-100% | 222-252 kPa (25-31 psi) | 1080-129 kPa (78-136 psi) | 13°C (55°F) |
19-24°C (66-75°F) | Less than 40% | 231-261 kPa (25-31 psi) | 1220-1460 kPa (109-173 psi) | 14°C (57°F) |
Greater than 40% | 251-281 kPa (25-35 psi) | 1220-1500 kPa (116-187 psi) | 16°C (61°F) | |
25-29°C (76-85°F) | Less than 35% | 251-281 kPa (25-34 psi) | 1360-1590 kPa (151-208 psi) | 16°C (61°F) |
35-60% | 259-289 kPa (25-36 psi) | 1380-1620 kPa (158-215 psi) | 17°C (63°F) | |
Greater than 60% | 275-305 kPa (26-38 psi) | 1390-1680 kPa (164-231 psi) | 19°C (66°F) | |
30-35°C (86-95°F) | Less than 30% | 276-306 kPa (27-39 psi) | 1470-1730 kPa (193-261 psi) | 19°C (66°F) |
Greater than 30% | 287-317 kPa (30-41 psi) | 1500-1800 kPa (203-282 psi) | 20°C (68°F) | |
36-41°C (96-105°F) | Less than 20% | 297-327 kPa (32-44 psi) | 1590-1840 kPa (224-283 psi) | 70°C (21°F) |
20-40% | 309-339 kPa (33-44 psi) | 1320-1930 kPa (229-300 psi) | 22°C (72°F) | |
Greater than 40% | 320-350 kPa (34-44 psi) | 1690-2020 kPa (244-316 psi) | 24°C (75°F) | |
42-46°C (106-115°F) | Less than 20% | 319-349 kPa (38-49 psi) | 1720-1960 kPa (264-319 psi) | 23°C (73°F) |
Greater than 20% | 332-362 kPa (38-48 psi) | 1760-2070 kPa (271-338 psi) | 24°C (75°F) | |
47-49°C (116-120°F) | Less than 30% | 339-369 kPa (43-51 psi) | 1880-2090 kPa (307-350 psi) | 25°C (77°F) |