Tools Required
J 45878 Combustible Gas Detector
Removal Procedure
- Relieve the CNG fuel system pressure. Refer to
Fuel Pressure Relief
.
- Lower the rear seat.
- Loosen the lower vent hose clamp.
- Pull the vent hose from the HPR.
- Disconnect the HPR to the HPL fuel line from the HPR.
- Remove the HPR inlet fitting (6).
- Remove the spring (4).
- Remove the filter (3).
- Remove the seal (2).
Installation Procedure
- Install a new seal (2).
- Install a new filter (3).
- Install a new spring (4).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the HPR inlet fitting (6) with a new O-ring (5). Lubricate the O-ring with petroleum jelly or the equivalent.
Tighten
Tighten the HPR inlet fitting to 48 N·m (35 lb ft).
- Connect the HPL to HPR fuel line to the HPR using a new O-ring face seal. Lubricate the O-ring with petroleum jelly or the equivalent.
Tighten
Tighten the fuel line fitting to 24 N·m (18 lb ft).
- Connect the HPL power electrical connector.
- Start the engine. Inspect for CNG fuel leaks at each serviced fitting using the J 45878
.
- Install the vent hose to the HPR.
Tighten
Tighten the vent hose clamp to 2 N·m (18 lb in).
- Raise the rear seat.