Removal Procedure
- Disconnect the evaporative
emission (EVAP) vent hose (3) from the EVAP canister vent valve (6).
- Disconnect the EVAP canister vent harness connector (5).
- Remove the EVAP canister vent valve (6) from the clip on the EVAP
canister bracket.
Installation Procedure
- Install the EVAP canister
vent valve (6) to the clip on the EVAP canister bracket.
- Connect the EVAP canister vent harness connector (5).
- Connect the EVAP vent hose (3) to the EVAP canister vent valve
(6).