GM Service Manual Online
For 1990-2009 cars only

Battery Negative Cable Disconnection and Connection Single Battery

Removal Procedure

Caution: Refer to Battery Disconnect Caution in the Preface section.

  1. Turn off all the lamps and accessories.
  2. Turn the ignition OFF.

  3. Object Number: 662092  Size: SH
  4. Remove the battery ground or negative cable and bolt from the battery for 8.1L.

Installation Procedure


Object Number: 662092  Size: SH

Caution: Refer to Battery Disconnect Caution in the Preface section.

Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

Important: Clean any existing corrosion from the battery terminal bolt flange and the battery cable end.

Install the battery ground or negative cable and bolt to the battery.

Tighten
Tighten the battery terminal bolt to 17 N·m (13 lb ft).

Battery Negative Cable Disconnection and Connection Auxiliary Battery

Removal Procedure

Caution: Refer to Battery Disconnect Caution in the Preface section.

  1. Turn off all the lamps and accessories.
  2. Turn the ignition OFF.

  3. Object Number: 662415  Size: SH
  4. Remove the battery ground or negative cable and bolt from the battery 8.1L.

  5. Object Number: 700829  Size: SH
  6. Remove the battery ground or negative cable and bolt from the battery for the 6.5L Diesel.

Installation Procedure


    Object Number: 662415  Size: SH

    Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  1. Connect the battery ground or negative cable and bolt from the battery 8.1L.
  2. Tighten
    Tighten the battery terminal bolt to 17 N·m (13 lb ft).


    Object Number: 700829  Size: SH
  3. Connect the battery ground or negative cable and bolt from the battery for the 6.5L (Diesel).
  4. Tighten
    Tighten the battery terminal bolt to 17 N·m (13 lb ft).