Generator Bracket Replacement for Chevrolet Chevy C Cab/Chassis HD (GMT 400) 2005
Generator Bracket Replacement L18
Removal Procedure
- Remove the generator.
Refer to
Generator Replacement
.
- Remove the drive belt tensioner. Refer to
Drive Belt Tensioner Replacement
in Engine Mechanical - 8.1L .
- Remove the drive belt idler pulley. Refer to
Drive Belt Idler Pulley Replacement
in Engine Mechanical - 8.1L
.
- Remove the generator bracket bolt (2) and nut.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator
bracket bolt (2) and nut.
Tighten
| • | Tighten the generator bracket bolt to 50 N·m (37 lb ft). |
| • | Tighten the generator bracket nut to 41 N·m (30 lb ft). |
- Install the drive belt idler pulley. Refer to
Drive Belt Idler Pulley Replacement
in Engine Mechanical - 8.1L
.
- Install the drive belt tensioner. Refer to
Drive Belt Tensioner Replacement
in Engine Mechanical - 8.1L .
- Install the generator. Refer to
Generator Replacement
.