Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. Connecting a scan tool to the DLC allows communication with the modules for diagnostic purposes. DTCs may be set due to this symptom and during this diagnostic procedure. Complete the diagnostic procedure in order to ensure all the DTCs are diagnosed and cleared from memory.
When the class 2 serial data circuit:
• | Is shorted to ground |
• | Is shorted to voltage |
• | Opens |
The following DTCs may set:
• | U1300 |
• | U1301 |
• | U1305 |
Refer to DTC U1300, U1301, or U1305 .
The numbers below refer to the step numbers on the diagnostic table.
A partial malfunction in the class 2 serial data circuit uses a different procedure from a total malfunction of the class 2 circuit. The following modules communicate on the class 2 serial data circuit:
• | The electronic brake control module (EBCM) |
• | The powertrain control module (PCM) |
• | Vehicle theft deterrent (VTD) |
The following DTCs may be retrieved with a history status, but are not the cause of the present condition.
• | U1300 |
• | U1301 |
• | U1305 |
A State of Health DTC with a history status may be present along with a U1000 or U1255 having a current status. This indicates that the malfunction occurred when the ignition was ON.
DLC terminal 2 and terminal 5 provide the connection to the class 2 serial data circuit and the signal ground circuit respectively.
A poor connection at terminal A would cause this condition but will not set a DTC.
An open in the class 2 serial data circuit will prevent the scan tool from communicating with the module. This condition will not set a DTC.
This test isolates the PCM class 2 serial data circuit.
This test isolates the EBCM class 2 serial data circuit.
This test isolates the VTD class 2 serial data circuit.
If there are no current DTCs that begin with a U, the communication malfunction has been repaired.
The communication malfunction may have prevented diagnosis of the customer complaint.
Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
Schematic Reference: Data Link Connector Schematics | |||||||
1 | Does the scan tool power up? | Go to Step 2 | |||||
Does the scan tool communicate with any module on the class 2 circuit? | Go to Step 3 | Go to Step 7 | |||||
Did you record any DTCs in the range of U1000 to U1255? | Go to Step 4 | Go to Diagnostic Aids | |||||
4 | Are the DTCs U1300, U1301 or U1305 retrieved from any module? | Go to Step 5 | Go to Step 6 | ||||
5 |
Important:: Turn ON the ignition, with the engine OFF, when testing for a short to voltage. Use the DMM MIN/MAX function to capture intermittent conditions. Test the class 2 serial data circuit for an intermittent short to ground or an intermittent short to voltage. Refer to the following in Wiring Systems: Did you find and correct the condition? | Go to Step 16 | Go to Step 6 | ||||
Is U1000 or U1255 the only DTC displayed in the previously specified range? | Go to DTC U1000 and U1255 | Go to DTC U1001-U1254 | |||||
Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to the applicable Diagnostic System Check | Go to Step 8 | |||||
8 | Test the DLC signal ground circuit terminal 5 for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to the applicable Diagnostic System Check | Go to Step 9 | ||||
Inspect S150 and S280. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to the applicable Diagnostic System Check | Go to Step 10 | |||||
Test the class 2 circuit for an open or a short. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to the applicable Diagnostic System Check | Go to Step 11 | |||||
Are you able to communicate with any class 2 modules? | Go to Step 15 | Go to Step 12 | |||||
Are you able to communicate with any class 2 modules? | Go to Step 15 | Go to Step 13 | |||||
Are you able to communicate with any class 2 modules? | Go to Step 15 | Go to Step 14 | |||||
14 | Inspect for poor connections at the class 2 serial data circuit of the module that is not communicating. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 | ||||
15 | Replace the module which is not communicating. Refer to the appropriate repair instructions:
Did you complete the replacement? | Go to Step 16 | -- | ||||
The scan tool may require a power up reset before communication will occur due to a short on the class 2 circuit. Remove the scan tool prior to performing this test. Did you record any DTCs which begin with a "U" and with a current status? | Go to Step 18 | Go to Step 17 | |||||
Did you record any DTCs which do not begin with a "U"? | Go to Step 18 | Go to Step 19 | |||||
18 | Diagnose the DTCs as directed by the diagnostic procedures for the particular module or malfunction. Refer to the applicable Diagnostic System Check. Did you complete the action? | Go to Step 19 | -- | ||||
19 | Did you diagnose all of the DTCs? | Go to Step 20 | Go to Step 18 | ||||
20 | Use the scan tool in order to clear the DTCs. Did you complete the action? | System OK | -- |