The throttle position (TP) sensor is a potentiometer. The control module supplies the TP sensor a reference voltage, a signal, and ground circuits. When the throttle is depressed, the TP sensor signal rises to near the reference voltage. When the throttle is released, the TP sensor signal decreases from the reference voltage. The control module monitors the TP sensor signal circuit voltage in order to determine the throttle blade angle, or opening.
This DTC is designed to detect a TP sensor signal voltage higher than the possible operating range of a normally functioning TP sensor.
The engine is running.
The TP sensor signal voltage is more than 4.7 volts for 1 second or more.
• | The control module illuminates the malfunction indicator lamp (MIL) the first time the diagnostic runs and fails. |
• | The control module will set the DTC and records the operating conditions at the time the diagnostic fails. The control module stores the failure information in the scan tools Freeze Frame/Failure Records. |
• | The control module turns OFF the MIL after 3 consecutive drive trips when the test has run and passed. |
• | A history DTC will clear if no fault conditions have been detected for 40 warm-up cycles. A warm-up cycle occurs when the coolant temperature has risen 22°C (40°F) from the startup coolant temperature and the engine coolant reaches a temperature that is more than 70°C (158°F) during the same ignition cycle. |
• | Use a scan tool in order to clear the DTCs. |
The scan tool reads the throttle position in volts. The scan tool should read about 0.45 to 0.85 volt with the throttle closed and the ignition switch turned ON or at idle. The voltage should increase at a steady rate as the throttle is moved toward the Wide Open Throttle (WOT).
The scan tool reads the throttle angle percentage. 0 percent at closed throttle. 100 percent at Wide Open Throttle (WOT).
Scan the TP sensor while depressing the accelerator pedal with the engine turned off and the ignition turned on. The display should vary from below the 1.25 volts (1250 mV) when the throttle was closed to over 4.5 volts (4500 mV) when the throttle is held at WOT position.
This DTC will result if the TP ground circuit is open or the TP signal circuit is shorted to voltage.
Refer to Symptoms .
The numbers below refer to the step numbers in the diagnostic table.
If the TP signal measures more than 4.8 volts, then the conditions exists.
With the TP sensor disconnected, and if the VCM and the wiring are okay, the TP signal should go below 0.25 volt. This test could set a DTC P0122.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Important: Before clearing the DTCs, use the scan tool Capture Info to save the Freeze Frame and Failure Records for reference. The control module's data is deleted once the Clear Info function is used. Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
Does the scan tool display a TP sensor voltage more than the specified value? | 4.7 V | |||
Does the scan tool display a TP sensor voltage less than the specified value? | 0.25 V | |||
4 | The DTC is intermittent. Are any additional DTCs stored? | -- | Go to the applicable DTC table | Go to Diagnostic Aids |
5 | Measure the 5 volt reference circuit at the TP sensor harness connector with a J 39200 DMM connected to a ground. Is the voltage more than the specified value? | 5.2 V | ||
6 | Probe the TP sensor ground circuit at the TP sensor harness connector with a test lamp connected to B+. Is the test lamp on? | -- | ||
7 | Replace the TP sensor. Refer to Throttle Position Sensor Replacement . Is the action complete? | -- | -- | |
8 | Check for a short to voltage in the TP sensor signal circuit. Did you find a problem? | -- | ||
9 |
Is the voltage more than the specified value? | 0 V | ||
10 | Measure the voltage on the MAP sensor 5 volt reference circuit at the VCM C3 connector with a J 39200 DMM connected to a ground. Is the voltage more than the specified value? | 0 V | ||
11 | Repair the open in the TP sensor ground circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
12 | Repair the circuit as necessary. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
13 | Repair the short to voltage on the 5 volt reference circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
14 |
Is the action complete? | -- | -- | |
15 |
Does the scan tool indicate the diagnostic Passed? | -- | ||
16 | Does the scan tool display any additional undiagnosed DTCs? | -- | Go to the applicable DTC table | System OK |