The camshaft position (CMP) sensor is a sensor designed to detect changes in a magnetic field. The control module supplies the CMP sensor with signal and ground circuits. Ignition voltage is supplied to the CMP sensor by an independent circuit. The CMP sensor produces a magnetic field whenever the ignition is ON. The CMP sensor is mounted near a reluctor wheel that is attached to the distributor shaft. When the distributor shaft rotates, or when the engine is cranking or running, the reluctor wheel changes the magnetic field. The CMP sensor converts each change in the magnetic field into a PULSE. The number of teeth on the reluctor wheel determines how many pulses the CMP sensor detects per camshaft rotation. The control module uses the CMP sensor signal in order to calculate the correct timing for sequential fuel injection.
If the VCM does not detect the CMP signal while the engine is running this DTC will be set.
The engine is running.
The camshaft position sensor reference pulse is not detected once every two crankshaft revolutions.
• | The control module illuminates the malfunction indicator lamp (MIL) if a failure is detected during 2 consecutive key cycles. |
• | The control module sets the DTC and records the operating conditions at the time the diagnostic failed. The failure information is stored in the scan tool Freeze Frame/Failure Records. |
• | The control module turns OFF the MIL after 3 consecutive drive trips when the test has run and passed. |
• | A history DTC will clear if no fault conditions have been detected for 40 warm-up cycles. A warm-up cycle occurs when the coolant temperature has risen 22°C (40°F) from the startup coolant temperature and the engine coolant reaches a temperature that is more than 70°C (158°F) during the same ignition cycle. |
• | Use a scan tool in order to clear the DTCs. |
Electro-magnetic interference from the ignition coil or the spark plug wires could cause a poor signal condition in the CMP signal circuit to the VCM. Ensure that the CMP sensor circuitry is routed correctly. Also check for the installation of aftermarket accessories and harnesses that can create an electromagnetic interference.
Refer to Symptoms
An intermittent may be caused by any of the following conditions:
• | A poor connection |
• | Rubbed through wire insulation |
• | A broken wire inside the insulation |
Thoroughly check any circuitry that is suspected of causing the intermittent complaint. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems.
If a repair is necessary, refer to Wiring Repairs or Connector Repairs in Wiring Systems.
The number(s) below refer to the step number(s) in the diagnostic table.
This step determines if the DTC P0340 is the result of a hard failure or an intermittent condition.
This step will check for a signal output from the CMP sensor. The signal can also be read in AC voltage, approximately 5-7 volts AC.
If there is not any additional DTCs set refer to Diagnostic Aids for examples of conditions that could cause an intermittent loss of signal from the CMP sensor.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Important: Before clearing the DTCs, use the scan tool Capture Info to save the Freeze Frame and Failure Records for reference. The control module's data is deleted once the Clear Info function is used. Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
Does the scan tool indicate this Diagnostic Ran and Passed? | -- | |||
3 |
Is the test lamp ON? | -- | ||
4 | Probe the CMP sensor ground circuit at the CMP sensor harness connector with a test lamp connected to B+. Is the test lamp ON? | -- | ||
Important: The red (positive) lead from the DMM must be connected to the CMP (1X) signal circuit. Is the duty cycle near the specified value? | 50% | |||
6 |
Did you find a problem? | -- | ||
7 | Check for a short to ground or a short to voltage on the CMP sensor 1x signal circuit. Did you find a problem? | -- | ||
This DTC is intermittent. Are any additional DTCs stored? | -- | Go to the applicable DTC table | Go to Diagnostic Aids | |
9 | Repair the open in the CMP sensor ignition positive voltage circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
10 | Repair the open in the CMP sensor ground circuit. Is the action complete? | -- | -- | |
11 | Check for a poor connection at the CMP sensor. Did you find a problem? | -- | ||
12 | Replace the Camshaft Position sensor. Refer to Camshaft Position Sensor Replacement . Is the action complete? | -- | -- | |
13 | Check for a poor connection at the VCM. Did you find a problem? | -- | ||
14 | Repair the circuit as necessary. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the action complete? | -- | -- | |
15 |
Is the action complete? | -- | -- | |
16 |
Does the scan tool indicate the diagnostic Passed? | -- | ||
17 | Does the scan tool display any additional undiagnosed DTCs? | -- | Go to the applicable DTC table | System OK |