Whenever the electric-shift motor is turned ON or OFF the motor and the electrical circuits are tested both in the de-energized and energized condition. If one or both voltage relays fail to detect the proper voltage after energizing or de-energized and energized condition. If one or both of the voltage relays fail to detect the proper voltage after energizing or de-energizing, the shift is aborted by the TCCM and a DTC of 3 is stored in order to indicate a faulty TCCM motor circuit.
If one or both relays fail to detect the proper voltage after de-energizing, both relays are turned ON by the TCCM, (even with the ignition switch positioned OFF) in order to prevent the motor from running. The TCCM then stores a DTC of 3 in order to indicate a faulty TCCM motor circuit. All of the status lamps blink three times, stop, and repeat the blinking continuously in order to alert the driver that the electronic shift system requires immediate repair. The battery will drain when this condition occurs, regardless of the ignition switch position.