The optical sensor provides a pump cam signal to the PCM by counting pulses on the sensor disk located in the injection pump. The pump cam is one of the most important inputs by the PCM for fuel control and timing. This test monitors the number of crankshaft position pulses that have occurred since the last cam pulse. The physical one to one correspondence between the pump cam and the crankshaft implies if more crank pulses are detected than cam pulses, cam pulses have been missed.
• | The PCM performs this DTC diagnostic continuously. |
• | The engine is operating. |
• | The number of consecutive missing cam pulses is more than or equal to 8. |
• | All diagnostic set conditions met for 2 seconds. |
• | The PCM illuminates the malfunction indicator lamp (MIL) on the first consecutive drive trip that the diagnostic runs and fails. |
• | The Freeze Frame records the operating conditions at the time of failure and updates the Failure Records. |
• | The PCM will activate Back Up fuel. |
• | The PCM will turn the MIL off after three consecutive trips without a fault condition. |
• | A History DTC clears after forty consecutive warm-up cycles, if this or any other emission related diagnostic does not report any failures |
• | The use of a scan tool. |
Intermittent DTCs (P0251, P0370 and P1216) may be caused by air entering the fuel system when fuel levels get below 1/8 of a tank while performing hard acceleration or turning maneuvers. It's also possible that a P0251, P0370 and P1216 will set the if vehicle has run out of fuel. Customer driving habits should be checked to determine if the vehicle has been performing in these manners. If the vehicle has been performing in these conditions, bleed the fuel system of all air and test drive the vehicle.
When the PCM is in backup fuel, fast idle and poor performance problems will exist.
An intermittent condition can be caused by the following:
• | Poor connections. |
• | Rubbed through wire insulation. |
• | Broken wire inside the insulation. |
Number(s) below refer to the step number(s) on the Diagnostic Table.
This step will determine if this is a hard or intermittent DTC.
This step will determine if there is a 5 volt reference.
This step will check to see if the sensor is sending a signal back to the PCM.
The PCM supplies 5 volts on the signal circuit. This step determines if that voltage is present, not present, or too much voltage is present.
This step determines if the signal circuit is shorted to 5V. A normal CAM signal circuit will have 3-5 mA. Any reading over 50 mA indicates a short to 5V.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Important: Before clearing the DTCs, use the scan tool Capture Info to save the Freeze Frame and failure records for reference. The control module's data is deleted once the Clear Info function is used. Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
2 | Is the DTC P0370 set also? | -- | Go to DTC P0370 Timing Reference High Resolution System Performance | |
Does scan tool display the specified value? | 8 | |||
4 | The DTC is intermittent. If no additional DTCs are stored, refer to Diagnostic Aids. If additional DTCs were stored refer to the applicable DTC table(s) first. Are any additional DTCs stored? | -- | Go to the Applicable DTC Table | Go to Diagnostic Aids |
Is the voltage within the specified value? | 4.8-5.2V | |||
6 | Probe the sensor ground circuit with a test light connected to B+ at the harness connector. Is the test light ON? | -- | ||
Is the Hertz reading at the specified value? | 60 Hz (± 3 Hz) | |||
8 |
Was the Optical sensor 5 volt reference circuit open or shorted to ground? | -- | ||
9 |
Did you perform a repair? | -- | ||
10 | Check the Optical/Fuel temperature 5 volt reference circuit for a proper connection at the PCM and replace terminal if necessary. Did the terminal require replacement? | -- | ||
Is the voltage within the specified value? | 4.8-5.2V | |||
12 | Is the voltage greater than the specified value? | 4.8-5.2V | ||
13 | Repair the short to battery/ignition voltage on the CAM signal circuit. Is the action complete? | -- | -- | |
14 |
Was the CAM signal circuit open or shorted to ground? | -- | ||
15 | Check for a proper connection at the PCM harness terminal and replace the terminal if necessary. Did the terminal require replacement? | -- | ||
With a DMM J 39200 set to the mA scale, measure the current between the CAM signal circuit and the ground circuit at the Optical/Fuel temperature sensor electrical connector. Is the current less than the specified value? | 50 mA | |||
17 | Repair the short to reference voltage on the CAM signal circuit. Is the action complete? | -- | -- | |
18 |
Was a problem found? | -- | ||
19 | Replace the injection pump. Refer to Fuel Injection Pump Replacement . Important: The new injection pump must be timed. Refer to Fuel Injection Pump Timing Adjustment . Is the action complete? | -- | -- | |
20 | Replace the PCM. Important: The new PCM must be programmed. Refer to Powertrain Control Module Replacement/Programming . Is the action complete? | -- | -- | |
21 |
Does the scan tool indicate the diagnostic Passed? | -- | ||
22 | Does the scan tool display any additional undiagnosed DTCs? | -- | Go to the Applicable DTC Table | System OK |